ASTM standards Grade steel material of seamless steel pipe
Overview
Standard: ASTM standard
Grade Group: GrA, GrB, P5,P9,P11,P22
Thickness: 1 - 100 mm
Outer Diameter(Round): 10 - 1000 mm
Length: Fixed length or random length
Section Shape: Round
Place of Origin: China
Certification: ISO9001:2008
Alloy Or Not: seamless carbon steel
Application: Steel Pipe
Surface Treatment: As customer's requirement
Technique: Hot Rolled/ cold drawn
Heat treatment: Normalizing
Special Pipe: Thick Wall Pipe
Usage: Construction, Fluid Transportation, Boiler and Heat Exchanger
Test: ET/UT
Main Grade
Material |
Pipes |
Fittings |
Flanges |
Valves |
Bolts & Nuts |
|
Carbon Steel |
A106 Gr A |
A234 Gr WPA |
A105 Gr A |
A216 Gr WCB |
A193 Gr B7 |
GB3077 35GrMoA GB699 35 |
A106 Gr B |
A234 Gr WPB |
A105 Gr B |
A216 Gr WCB |
|||
A106 Gr C |
A234 Gr WPC |
A105 Gr C |
A216 Gr WCB |
|||
Carbon Steel |
A335 Gr P1 |
A234 Gr WP1 |
A182 Gr F1 |
A217 Gr WC1 |
A193 Gr B16 |
HG20634 |
A335 Gr P11 |
A234 Gr WP11 |
A182 Gr F11 |
A217 Gr WC6 |
|||
A335 Gr P12 |
A234 Gr WP12 |
A182 Gr F12 |
A217 Gr WC6 |
|||
A335 Gr P22 |
A234 Gr WP22 |
A182 Gr F22 |
A217 Gr WC9 |
|||
A335 Gr P5 |
A234 Gr WP5 |
A182 Gr F5 |
A217 Gr C5 |
|||
A335 Gr P9 |
A234 Gr WP9 |
A182 Gr F9 |
A217 Gr C12 |
|||
Carbon Steel Alloy |
A333 Gr 5 |
A420 Gr WPL6 |
A350 Gr LF2 |
A352 Gr LCB |
A320 Gr L7 |
|
A333 Gr 3 |
A420 Gr WPL3 |
A350 Gr LF3 |
A352 Gr LC3 |
|||
Austenitic |
A312 Gr TP304 |
A403 Gr WP304 |
A182 Gr F304 |
A182 Gr F304 |
A193 Gr B8 |
|
A312 Gr TP316 |
A403 Gr WP316 |
A182 Gr F316 |
A182 Gr F316 |
|||
A312 Gr TP321 |
A403 Gr WP321 |
A182 Gr F321 |
A182 Gr F321 |
|||
A312 Gr TP347 |
A403 Gr WP347 |
A182 Gr F347 |
A182 Gr F347 |
Test Requirement
Show some usual test for reference,for different standard ,please see detail standard.
Hydraustatic Test:
The Steel Pipe Should Be Tested Hydraulically One By One. The Maximum Test Pressure Is 20 MPa. Under The Test Pressure, The Stabilization Time Should Be Not Less Than 10 S, And The Steel Pipe Should Not Leak.
After The User Agrees, The Hydraulic Test Can Be Replaced By Eddy Current Testing Or Magnetic Flux Leakage Testing.
Nondestructive Test:
Pipes That Require More Inspection Should Be Ultrasonically Inspected One By One. After The Negotiation Requires The Consent Of The Party And Is Specified In The Contract, Other Non-Destructive Testing Can Be Added.
Flattening Test:
Tubes With An Outer Diameter Greater Than 22 Mm Shall Be Subjected To A Flattening Test. No Visible Delamination, White Spots, Or Impurities Should Occur During The Entire Experiment.
Flaring Test:
According To The Requirements Of The Purchaser And Stated In The Contract, The Steel Pipe With Outer Diameter ≤76mm And Wall Thickness ≤8mm Can Be Done Flaring Test . The Experiment Was Performed At Room Temperature With A Taper Of 60 °. After The Flaring, The Flaring Rate Of The Outer Diameter Should Meet The Requirements Of The Following Table, And The Test Material Must Not Show Cracks Or Rips